  • Switches-DPDT

    Macom Technology Solutions Holdings Inc.

    At MACOM we offer an extensive collection of switches covering multiple commercial and aerospace and defense markets. Our product portfolio has a broad frequency spectrum from DC to 70 GHz. Our silicon Heterolithic Microwave Integrated Circuit (HMIC) PIN diode process is ideal for high power and broadband switches operating from 50 MHz to 26 GHz. Our AlGaAs PIN diode process can extend the upper frequency range of our switch die beyond 70 GHz and is ideal for instrumentation and radar applications. Our GaAs pHEMT and MESFET technology is ideal for fast switching and low control voltage switches optimized for both narrow band and broadband applications. Our 75 Ohm absorptive switches are designed specifically for demanding CATV, FTTx and DBS Infrastructure and CPE applications.

  • Switches-SP8T

    Macom Technology Solutions Holdings Inc.

    At MACOM we offer an extensive collection of switches covering multiple commercial and aerospace and defense markets. Our product portfolio has a broad frequency spectrum from DC to 70 GHz. Our silicon Heterolithic Microwave Integrated Circuit (HMIC) PIN diode process is ideal for high power and broadband switches operating from 50 MHz to 26 GHz. Our AlGaAs PIN diode process can extend the upper frequency range of our switch die beyond 70 GHz and is ideal for instrumentation and radar applications. Our GaAs pHEMT and MESFET technology is ideal for fast switching and low control voltage switches optimized for both narrow band and broadband applications. Our 75 Ohm absorptive switches are designed specifically for demanding CATV, FTTx and DBS Infrastructure and CPE applications.

  • Switches-SPDT

    Macom Technology Solutions Holdings Inc.

    At MACOM we offer an extensive collection of switches covering multiple commercial and aerospace and defense markets. Our product portfolio has a broad frequency spectrum from DC to 70 GHz. Our silicon Heterolithic Microwave Integrated Circuit (HMIC) PIN diode process is ideal for high power and broadband switches operating from 50 MHz to 26 GHz. Our AlGaAs PIN diode process can extend the upper frequency range of our switch die beyond 70 GHz and is ideal for instrumentation and radar applications. Our GaAs pHEMT and MESFET technology is ideal for fast switching and low control voltage switches optimized for both narrow band and broadband applications. Our 75 Ohm absorptive switches are designed specifically for demanding CATV, FTTx and DBS Infrastructure and CPE applications.

  • Switches-SP3T

    Macom Technology Solutions Holdings Inc.

    At MACOM we offer an extensive collection of switches covering multiple commercial and aerospace and defense markets. Our product portfolio has a broad frequency spectrum from DC to 70 GHz. Our silicon Heterolithic Microwave Integrated Circuit (HMIC) PIN diode process is ideal for high power and broadband switches operating from 50 MHz to 26 GHz. Our AlGaAs PIN diode process can extend the upper frequency range of our switch die beyond 70 GHz and is ideal for instrumentation and radar applications. Our GaAs pHEMT and MESFET technology is ideal for fast switching and low control voltage switches optimized for both narrow band and broadband applications. Our 75 Ohm absorptive switches are designed specifically for demanding CATV, FTTx and DBS Infrastructure and CPE applications.

  • Power Supply 302D

    TOMSAD

    reliable and precise power of the output DC stabilization and digital LED displays. The output voltage is adjustable from 0 ~ 15V DC in smoothly with the knobs to control coarse and precise. Output current is regulated (limited) fluent in 0.6A ~ 2A. Securing the power supply protects it against accidental short circuits, and thus against overload and damage. In addition, the power supply has 5 fixed output voltages: 1.5 V, 3.6 V, 4.8 V, 6 V and 7.2 V, specially designed for mobile services, power systems and electronic components, etc. can be used in the design of electronic products, scientific work in laboratories, production lines and in teaching. Power can be used in the design of electronic products, scientific papers, laboratories, production lines and in teaching.

  • Power Supply 1502D

    TOMSAD

    reliable and precise power of the output DC stabilization and digital LED displays. The output voltage is adjustable from 0 ~ 15V DC in smoothly with the knobs to control coarse and precise. Output current is regulated (limited) fluent in 0.6A ~ 2A. Securing the power supply protects it against accidental short circuits, and thus against overload and damage. In addition, the power supply has 5 fixed output voltages: 1.5 V, 3.6 V, 4.8 V, 6 V and 7.2 V, specially designed for mobile services, power systems and electronic components, etc. can be used in the design of electronic products, scientific work in laboratories, production lines and in teaching. Power can be used in the design of electronic products, scientific papers, laboratories, production lines and in teaching.

  • Power Supply 605D-II

    TOMSAD

    reliable and precise power of the output DC stabilization and digital LED displays. The output voltage is adjustable from 0 ~ 15V DC in smoothly with the knobs to control coarse and precise. Output current is regulated (limited) fluent in 0.6A ~ 2A. Securing the power supply protects it against accidental short circuits, and thus against overload and damage. In addition, the power supply has 5 fixed output voltages: 1.5 V, 3.6 V, 4.8 V, 6 V and 7.2 V, specially designed for mobile services, power systems and electronic components, etc. can be used in the design of electronic products, scientific work in laboratories, production lines and in teaching. Power can be used in the design of electronic products, scientific papers, laboratories, production lines and in teaching.

  • Hydrophone

    TC4047 - Teledyne Marine RESON B.V.

    The TC4047 miniature hydrophone offers a useable frequency range from 1kHz to 170kHz. The hydrophone incorporates a high quality 20dB low-noise pre-amplifi er which provides optimal conditions for signal transmission. The high sensitivity provides excellent signal to noise ratio and immunity against induced cable noise. The hydrophone is omnidirectional up-to 100kHz and has uniform receiving characteristic from 1kHz to 100kHz. An insert calibration circuit enables remote testing of the hydrophone condition. The hydrophone comes with a SEACON connector. The sensor element is permanently encapsulated in Special formulated NBR to ensure long term reliability. The rubber has been specially compounded to ensure acoustic impedance close to that of water. The strainrelief and outer jacket of the cable is made of high density polyurethane. TC4047 can be used in sea or fresh water.

  • Wire Test Unit

    McGan Technology

    The Wire Testing Unit (WTU) is used in conjunction with the MMPD-8K kit or the MM5KV Kit purchased with the optional HV Red Wire and is used to easily test the continuity of electrosurgical cables used to connect the electrosurgical generator either to the active handpiece (e.g. laparoscopic instruments or forceps) or to the return electrode which completes the circuit between the generator and the patient. If the conductor is broken without damage to the cable’s jacket it can remain unseen and could be put into use for the electrosurgical operation causing the system to not properly function. By using the WTU you can test to ensure that the cables have continuity prior to actual usage in the operating room. This does not preclude the other tests that should be performed on these cables such as visually examining the cable for jacket damage including cracks, pinholes and abrasions and manually flexing the cable.

  • Medical Leakage Current Tester

    2675Y - Shenzhen Chuangxin Instruments Co., Ltd.

    The 2675Y Medical Leakage Current Tester Series Is The Test Equipment Used For Measuring Continuous Leakage Current And Patient Auxiliary Current Of Medical Electrical Equipment.It Designs And Products According To The GB9706.1_2020 (IEC60601-1:2012) .And The Test Circuit (MD)Input Impedance To Simulate The Body Impedance,It Accord With The Requirements Of GB9706.1-2020 (IEC60601-1:2012),The Test Current Can Run Up To 5A,And Provide Users With An Isolation Power Supply Which Adjustable Output Voltage For 0~250V Continuously Of The Basic Capacity Configuration For The 500VA And Provide Another 110% Voltage Source Of The Maximum Rated Voltage.It Can Satisfy The I,II, Various Types Of Equipment Test The Earth Leakage Current,Shell Leakage Current,Patient Leakage Current,Patient Auxiliary Leakage Current Under Normal Condition And The Single Fault.

  • ÷10, 500 MHz, 10 MΩ, Passive Probe (Total of 1 Per Channel)

    PP008-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm

    PP017-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm

    PP018-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • 10:1, 10 Mohm, 300 MHz Passive Probe

    PP016 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

  • ÷10, 500 MHz, 10 MΩ, Passive Probe

    PP009-1 - Teledyne LeCroy

    Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.

Get Help